Capability Deep-Dive

Steam Systems

Precision delivery of sterile steam reticulation and large volume thermal heating for high demand Healthcare and commercial laundry facilities.

Steam Systems - photo 1

Commercial steam systems generate and distribute steam for sterilisation, laundries and large-volume hot water. Goldman Plumbing designs, installs and maintains steam plant, reticulation and condensate systems for hospitals, day surgeries and commercial laundries, including steam plant replacements carried out in live hospitals in Sydney and Melbourne.

What does a steam system installation include?

Goldman's steam work covers steam generation and reticulation, condensate return, pressure reduction and control, insulation, and ongoing service and maintenance of steam plant. We have delivered steam services to numerous commercial laundries and healthcare facilities, where reliable, precisely controlled steam is essential to daily operations.

What are commercial steam systems used for?

Typical applications are hospital and day-surgery sterilising services (CSSD), commercial and industrial laundries, and large-volume thermal hot water.

Can steam plant be replaced in a live hospital?

Yes. At Bankstown Hospital, Goldman replaced the ageing domestic hot water and steam generation systems that underpin sterilisation, sanitation and everyday clinical operations. Isolations and temporary services were planned so hot water and steam supply to critical areas was maintained throughout, with works staged around clinical activity, and the new plant was handed over with certification and documentation.

At Austin Health in Melbourne, Goldman replaced the steam boiler plant in the hospital's boiler house, installing new packaged boilers, burners, economisers and flues craned in over the roof, along with steam and feedwater pipework, the distribution manifold, and electrical and controls. Steam supply to the hospital was maintained throughout testing, commissioning and handover.

At Wyong Hospital, Goldman replaced the steam boiler 1000 L water make-up tank and associated valves, drains and equipment, an approach chosen instead of relocating the existing header tank to reduce the shutdown time of essential services.

Which standards apply to steam piping?

Steam reticulation is pressure piping and is designed and installed to AS 4041, with in-service inspection supported to AS 3788, so systems are safe, compliant and documented.

At a Glance

Applications
Healthcare sterilisation and commercial laundries
Scope
Design, installation and maintenance
Delivers
Sterile steam and large-volume hot water
Standard
Pressure piping to AS 4041
References
Bankstown Hospital, Austin Health, Wyong Hospital

Quick Enquiry

About Steam Systems. We respond within one business day.

Frequently Asked Questions

Does Goldman Plumbing install and maintain commercial steam systems?
Yes. Goldman Plumbing designs, installs and maintains steam systems for healthcare facilities and commercial laundries, including steam plant replacements at Bankstown Hospital, Austin Health and Wyong Hospital.
What are commercial steam systems used for?
Healthcare sterilisation (CSSD) and commercial or industrial laundries, as well as large-volume thermal hot water delivery.
Can steam boilers be replaced without shutting down a hospital?
Yes, with careful staging. At Bankstown Hospital and Austin Health, Goldman planned isolations and temporary services so steam supply to the hospital was maintained throughout the changeover.
Can Goldman service existing steam plant as well as install new systems?
Yes. Goldman provides both installation of new steam reticulation and ongoing maintenance of existing steam systems.
Which standard applies to steam pipework?
Steam reticulation is pressure piping designed and installed to AS 4041, with in-service inspection supported to AS 3788.

Need this capability on your site?

Start Technical Conversation