Steam Systems
Precision delivery of sterile steam reticulation and large volume thermal heating for high demand Healthcare and commercial laundry facilities.

Commercial steam systems generate and distribute steam for sterilisation, laundries and large-volume hot water. Goldman Plumbing designs, installs and maintains steam plant, reticulation and condensate systems for hospitals, day surgeries and commercial laundries, including steam plant replacements carried out in live hospitals in Sydney and Melbourne.
What does a steam system installation include?
Goldman's steam work covers steam generation and reticulation, condensate return, pressure reduction and control, insulation, and ongoing service and maintenance of steam plant. We have delivered steam services to numerous commercial laundries and healthcare facilities, where reliable, precisely controlled steam is essential to daily operations.
What are commercial steam systems used for?
Typical applications are hospital and day-surgery sterilising services (CSSD), commercial and industrial laundries, and large-volume thermal hot water.
Can steam plant be replaced in a live hospital?
Yes. At Bankstown Hospital, Goldman replaced the ageing domestic hot water and steam generation systems that underpin sterilisation, sanitation and everyday clinical operations. Isolations and temporary services were planned so hot water and steam supply to critical areas was maintained throughout, with works staged around clinical activity, and the new plant was handed over with certification and documentation.
At Austin Health in Melbourne, Goldman replaced the steam boiler plant in the hospital's boiler house, installing new packaged boilers, burners, economisers and flues craned in over the roof, along with steam and feedwater pipework, the distribution manifold, and electrical and controls. Steam supply to the hospital was maintained throughout testing, commissioning and handover.
At Wyong Hospital, Goldman replaced the steam boiler 1000 L water make-up tank and associated valves, drains and equipment, an approach chosen instead of relocating the existing header tank to reduce the shutdown time of essential services.
Which standards apply to steam piping?
Steam reticulation is pressure piping and is designed and installed to AS 4041, with in-service inspection supported to AS 3788, so systems are safe, compliant and documented.
At a Glance
- Applications
- Healthcare sterilisation and commercial laundries
- Scope
- Design, installation and maintenance
- Delivers
- Sterile steam and large-volume hot water
- Standard
- Pressure piping to AS 4041
- References
- Bankstown Hospital, Austin Health, Wyong Hospital
Quick Enquiry
About Steam Systems. We respond within one business day.