Thermostatic Mixing Valves & Backflow Prevention Devices
Strict regulation and certification of thermostatic mixing valves (TMVs) and backflow prevention devices, safeguarding critical Health and Aged Care water supplies.

Thermostatic mixing valves (TMVs) limit the delivery temperature of warm water to protect people from scalding, and backflow prevention devices stop contaminated water flowing back into the drinking water supply. Goldman Plumbing's endorsed technicians test and service both for hospitals, aged care and accessible facilities across QLD, NSW, VIC and SA.
What is a thermostatic mixing valve?
A TMV is a testable valve that blends hot and cold water to regulate and restrict the temperature of warm water at the outlet. TMVs are common in aged care, hospitals and accessible facilities, where residents and patients are at higher risk of scalding.
How often should TMVs be serviced?
TMV owners are required to test their valves annually to the manufacturer's recommendations to maintain compliance with Australian Standards, with testing and servicing carried out to AS 4032. An additional endorsement on a plumbing licence is required to service a TMV, and Goldman's technicians hold the required endorsements.
What does a backflow prevention device do?
A backflow prevention device protects potable water supplies from cross-contamination by stopping water from a building's services flowing back into the supply. Backflow devices are testable every 12 months, with a test report sent to the local water authority as proof of testing. Device types and lodgement requirements vary, so check the requirements of your water authority.
Who can test backflow prevention devices?
Servicing and testing backflow prevention devices also requires an additional endorsement on a plumbing licence. Goldman Plumbing is licensed to carry out TMV and backflow prevention device testing and servicing throughout all states of Australia, with backflow devices tested to AS/NZS 2845.
What reports do you receive after testing?
Goldman Plumbing tests and services over five thousand TMVs and backflow prevention devices each year across QLD, NSW, VIC and SA. After each service, clients receive all TMV and backflow service reports for their compliance records, and Goldman lodges backflow compliance documentation with the facility's local water authority as required.
Can a warm water system be converted to TMVs?
Yes. At Woy Woy Hospital, Goldman converted the ground floor from a central warm water system to a thermostatic mixing valve warm water system, modifying pipework in numerous locations to suit the new valves. The project also included a new hot water ring main for the hospital's Rehabilitation Centre, fed by new hot water heaters and secondary circulation pumps with timer controls.
Related project
Related guides
At a Glance
- Applications
- Aged care, hospitals and accessible facilities
- Compliance
- Annual testing to AS 4032 and AS/NZS 2845
- Volume
- 5,000+ TMVs and backflow devices tested annually
- Coverage
- QLD, NSW, VIC and SA
- Licensing
- Endorsed plumbing licence required